Build a Plant Equipment Commissioning Acceptance Audit Packager — implementation
Linked challenge: Build a Plant Equipment Commissioning Acceptance Audit Packager
Prompt source
implementation103 lines11 sectionsNo variables1 code block
## Build
Cross-reference factory acceptance test checklists with simulated Sparkplug B device birth data and sensor ranges. Assemble audit-ready commissioning documentation for client handover.
## User
Industrial Project Engineer
## Workflow
1. Parse NBIRTH payloads and device metric definitions from simulated Sparkplug B streams.
2. Verify that instrument engineering units and metric ranges meet acceptance criteria.
3. Flag unannounced or missing device metrics required by contractual commissioning specs.
4. Synthesize a client-ready equipment commissioning acceptance summary packet.
## Interface
Web view showing contractual commissioning criteria, live metric bindings, and acceptance packet download button.
## Data
JSON dumps representing Sparkplug B NBIRTH templates, metric properties, and contract specification tables.
Starter examples below are synthetic. They are not downloaded records.
## Source
[Eclipse Sparkplug](https://raw.githubusercontent.com/eclipse-sparkplug/sparkplug/master/README.md)
Implements Sparkplug B NBIRTH metric metadata and property fields (e.g., engineering units, min/max limits).
## Tools
pydantic-ai, fastapi, jinja2.
Pydantic AI cleanly validates Sparkplug metric property types against contractual commissioning schemas.
Local or hosted LLM with strong schema enforcement and contract parsing capabilities.
## Deliverables
Submit runnable source, pinned dependencies, setup commands, a working interface, example outputs, and a recorded end-to-end demo. Include tests and an action log.
## Acceptance
- Flags metric range definitions that do not match project specification sheets.
- Validates presence of all mandatory Sparkplug B birth metadata properties.
- Outputs a valid equipment acceptance certificate in JSON format.
## Starter Examples
```json
[
{
"input": {
"contract_id": "CTR-9012",
"device_id": "CHILLER-EDGE-01",
"required_metrics": [
{
"name": "SupplyTemp",
"unit": "degC",
"min": -10,
"max": 50
}
],
"nbirth_payload": {
"metrics": [
{
"name": "SupplyTemp",
"properties": {
"eng_unit": "degC",
"eng_min": -10,
"eng_max": 50
}
}
]
}
},
"expected_output": {
"contract_id": "CTR-9012",
"device_id": "CHILLER-EDGE-01",
"acceptance_passed": true,
"discrepancies": [],
"certificate_status": "READY_FOR_SIGNATURE"
}
},
{
"input": {
"contract_id": "CTR-9012",
"device_id": "CHILLER-EDGE-02",
"required_metrics": [
{
"name": "SupplyTemp",
"unit": "degC",
"min": -10,
"max": 50
}
],
"nbirth_payload": {
"metrics": [
{
"name": "SupplyTemp",
"properties": {
"eng_unit": "degF",
"eng_min": 14,
"eng_max": 122
}
}
]
}
},
"expected_output": {
"contract_id": "CTR-9012",
"device_id": "CHILLER-EDGE-02",
"acceptance_passed": false,
"discrepancies": [
"Unit mismatch on SupplyTemp: expected degC, found degF"
],
"certificate_status": "REJECTED"
}
}
]
```
## Safety
Audit compilation only; does not transmit actuation or write commands to edge controllers.
Use mock external writes. Require human review before any real deployment.