Build an EnergyPlus Infiltration and Thermal Envelope Calibration Assistant — implementation

Linked challenge: Build an EnergyPlus Infiltration and Thermal Envelope Calibration Assistant

Prompt source

implementation65 lines11 sectionsNo variables1 code block
## Build
Evaluate whole-building blower door air leakage test data against EnergyPlus epJSON ZoneInfiltration objects. Calibrate air flow coefficients and thermal properties to reconcile measured operational infiltration with simulation models.

## User
Building Energy Modeler

## Workflow
1. Parse baseline commercial building energy models formatted in EnergyPlus epJSON schema.
2. Ingest field blower door leakage rates and building envelope surface area measurements.
3. Adjust ZoneInfiltration:DesignFlowRate flow per exterior surface area parameters.
4. Generate calibrated epJSON building input objects and output a calibration variance summary.

## Interface
Interactive parameter tuning panel with air-tightness curve plots and JSON schema diff viewers.

## Data
Use example EnergyPlus epJSON files from the EnergyPlus repo test suites and mock blower-door test logs.
Starter examples below are synthetic. They are not downloaded records.

## Source
[EnergyPlus](https://raw.githubusercontent.com/NREL/EnergyPlus/develop/README.md)
Leverages EnergyPlus epJSON input schema and ZoneInfiltration input objects described in the repository documentation.

## Tools
optuna, pydantic, FastAPI.
Optuna optimizes multi-zone infiltration coefficients to minimize the error between simulated leakage and field test curves.
Fast instruction LLM for checking parameter boundaries and summarizing energy model adjustments.

## Deliverables
Submit runnable source, pinned dependencies, setup commands, a working interface, example outputs, and a recorded end-to-end demo. Include tests and an action log.

## Acceptance
- Parses EnergyPlus epJSON ZoneInfiltration:DesignFlowRate objects accurately.
- Calculates calibrated design volume flow rates based on ACH50 field test measurements.
- Validates calibrated values against epJSON schema constraints and acceptable engineering boundaries.

## Starter Examples
```json
[
  {
    "input": {
      "zone_id": "Office_Floor_1",
      "exterior_surface_area_m2": 1200,
      "baseline_flow_per_zone_floor_area": 0.0003,
      "blower_door_ach50": 3.2,
      "zone_volume_m3": 3600
    },
    "expected_output": {
      "calibrated_design_flow_rate_m3_s": 0.576,
      "adjusted_flow_per_exterior_area": 0.00048,
      "variance_percentage": 60,
      "status": "calibrated"
    }
  },
  {
    "input": {
      "zone_id": "Server_Room",
      "exterior_surface_area_m2": 0,
      "baseline_flow_per_zone_floor_area": 0,
      "blower_door_ach50": 0,
      "zone_volume_m3": 400
    },
    "expected_output": {
      "calibrated_design_flow_rate_m3_s": 0,
      "adjusted_flow_per_exterior_area": 0,
      "variance_percentage": 0,
      "status": "interior_zone_skipped"
    }
  }
]
```

## Safety
Simulation inputs are validated against schema boundaries; no automated building equipment control overrides.
Use mock external writes. Require human review before any real deployment.