Build a Sparkplug B Multi-Zone Thermal Energy Optimizer — implementation
Linked challenge: Build a Sparkplug B Multi-Zone Thermal Energy Optimizer
Prompt source
implementation89 lines11 sectionsNo variables1 code block
## Build
Process Sparkplug B thermal oven metric updates and electric utility peak hours. Plan dynamic zone ramp-up sequences to minimize compound electrical peak demand charges.
## User
Process Operations Engineer
## Workflow
1. Parse Sparkplug B thermal zone telemetry payloads across multiple industrial curing ovens.
2. Evaluate cumulative instantaneous power against utility peak demand threshold ceilings.
3. Sequence oven pre-heating and ramp intervals to stagger overlapping peak loads.
4. Generate a thermal ramp scheduling plan for furnace control operators.
## Interface
Heatmap timetable illustrating staggered zone power curves against the site demand cap.
## Data
Generate synthetic JSON payloads following Sparkplug B v3.0 metric schemas for multi-zone industrial ovens.
Starter examples below are synthetic. They are not downloaded records.
## Source
[Eclipse Sparkplug](https://raw.githubusercontent.com/eclipse-sparkplug/sparkplug/master/README.md)
Uses Sparkplug B complex data types, metric properties, and dataset structures defined in Source 2.
## Tools
ray-serve, numpy.
Ray Serve enables scalable parallel evaluation of multi-zone thermal scheduling constraints across multiple production cells.
Local model for rule-checking or hosted API for thermal ramp plan explanation.
## Deliverables
Submit runnable source, pinned dependencies, setup commands, a working interface, example outputs, and a recorded end-to-end demo. Include tests and an action log.
## Acceptance
- Guarantees aggregate power remains below simulated 1.2 MW peak demand cap.
- Ensures all curing recipes achieve target soaking temperatures within required batch windows.
- Produces valid Sparkplug B compatible schedule proposal documents.
## Starter Examples
```json
[
{
"input": {
"ovens": [
{
"id": "OVEN-1",
"ramp_power_kw": 400,
"soak_power_kw": 120,
"ramp_min": 30,
"soak_min": 60
},
{
"id": "OVEN-2",
"ramp_power_kw": 500,
"soak_power_kw": 150,
"ramp_min": 40,
"soak_min": 45
}
],
"max_simultaneous_kw": 700
},
"expected_output": {
"oven_1_start_minute": 0,
"oven_2_start_minute": 30,
"peak_aggregate_kw": 620,
"demand_cap_breached": false
}
},
{
"input": {
"ovens": [
{
"id": "OVEN-3",
"ramp_power_kw": 600,
"soak_power_kw": 200,
"ramp_min": 45,
"soak_min": 90
},
{
"id": "OVEN-4",
"ramp_power_kw": 650,
"soak_power_kw": 250,
"ramp_min": 45,
"soak_min": 90
}
],
"max_simultaneous_kw": 800
},
"expected_output": {
"oven_3_start_minute": 0,
"oven_4_start_minute": 45,
"peak_aggregate_kw": 850,
"demand_cap_breached": true
}
}
]
```
## Safety
Read-only planning simulation; does not issue write commands to live furnace controllers.
Use mock external writes. Require human review before any real deployment.