Build a Solar Farm Water Pipeline Leak and Wash Outage Coordinator — implementation
Linked challenge: Build a Solar Farm Water Pipeline Leak and Wash Outage Coordinator
Prompt source
implementation84 lines11 sectionsNo variables1 code block
## Build
Correlate hydraulic pressure telemetry across utility-scale solar demineralized water distribution mains. Formulate isolation valving plans to contain pipe leaks without disrupting automated cleaning robot water stations.
## User
Solar plant balance-of-plant technicians and water distribution maintenance engineers
## Workflow
1. Ingest ultrasonic flowmeter and pressure sensor telemetry across the solar field cleaning water pipeline.
2. Isolate pipe bursts and locate low-pressure wash nodes using WNTR hydraulic simulation routines.
3. Reroute water flows across secondary loops to maintain pressure at automated robot refill docks.
4. Compile a valve isolation work ticket and wash reschedule plan for operations team verification.
## Interface
Solar field pipeline network map displaying pressure heatmaps, burst locations, and cleaning robot refill status.
## Data
WNTR synthetic rural distribution network files configured to match a 500MW solar plant demineralized water grid.
Starter examples below are synthetic. They are not downloaded records.
## Source
[Water Network Tool for Resilience](https://raw.githubusercontent.com/USEPA/WNTR/main/README.md)
Uses WNTR network models to simulate pipe bursts, leak discharges, and pressure-dependent delivery across wash lines.
## Tools
semantic-kernel, pydantic-ai, wntr, pandas.
semantic-kernel orchestrates complex enterprise telemetry analysis plugins and generates structured action plans.
Hosted LLM API capable of executing semantic kernel functions and generating clear operational steps.
## Deliverables
Submit runnable source, pinned dependencies, setup commands, a working interface, example outputs, and a recorded end-to-end demo. Include tests and an action log.
## Acceptance
- Detects and localizes pipeline bursts using nodal pressure drops simulated in WNTR.
- Identifies boundary isolation valves required to seal off the damaged pipeline segment.
- Calculates residual pressure at solar panel washing robot docking stations to confirm refill viability.
- Requires maintenance superintendent confirmation before issuing physical field isolation tickets.
## Starter Examples
```json
[
{
"input": {
"pipe_id": "W-MAIN-14",
"measured_flow_lps": 85,
"expected_flow_lps": 40,
"measured_pressure_bar": 1.2,
"downstream_refill_docks": [
"DOCK-01",
"DOCK-02"
]
},
"expected_output": {
"burst_detected": true,
"leak_discharge_est_lps": 45,
"valves_to_close": [
"VALVE-28",
"VALVE-29"
],
"docks_operational_via_loop": [
"DOCK-01"
],
"docks_starved": [
"DOCK-02"
],
"action_order": "Isolate W-MAIN-14; reroute DOCK-02 cleaning robot to DOCK-01."
}
},
{
"input": {
"pipe_id": "W-MAIN-08",
"measured_flow_lps": 38,
"expected_flow_lps": 37.5,
"measured_pressure_bar": 3.8,
"downstream_refill_docks": [
"DOCK-03"
]
},
"expected_output": {
"burst_detected": false,
"leak_discharge_est_lps": 0.5,
"valves_to_close": [],
"docks_operational_via_loop": [
"DOCK-03"
],
"docks_starved": [],
"action_order": "Normal operation; flow and pressure within tolerance."
}
}
]
```
## Safety
Simulation of hydraulic isolation only; physical valve operations require lockout-tagout protocol verification on site.
Use mock external writes. Require human review before any real deployment.