Build an Accelerator Chassis Power Budget and Throttling Reviewer — implementation
Linked challenge: Build an Accelerator Chassis Power Budget and Throttling Reviewer
Prompt source
implementation73 lines11 sectionsNo variables1 code block
## Build
Correlate server chassis electrical power caps with per-device DCGM utilization logs. Formulate dynamic power balancing schedules and throttling prevention plans using hosted Claude.
## User
Datacenter Power and Facilities Engineer
## Workflow
1. Ingest rack PDU power limits and per-accelerator DCGM power consumption telemetry using pandas.
2. Detect electrical headroom deficits where total peak draw risks tripping rack-level circuit breakers.
3. Invoke hosted Claude via Anthropic API to synthesize power cap balancing proposals across non-critical workers.
4. Generate a structured power allocation manifest detailing per-GPU watt limits validated via pydantic.
## Interface
Dashboard visualizing rack power envelope utilization and Claude-recommended power capping profiles.
## Data
Simplified synthetic app records representing power telemetry logs from server PDUs and DCGM metrics across 8-accelerator chassis.
Starter examples below are synthetic. They are not downloaded records.
## Source
[NVIDIA DCGM exporter](https://raw.githubusercontent.com/NVIDIA/dcgm-exporter/main/README.md)
Extracts DCGM power metrics (DCGM_FI_DEV_POWER_USAGE) and hardware power limit registers.
## Tools
dspy, anthropic, pandas, pydantic.
DSPy compiles robust prompt pipelines to guarantee hosted Claude produces schema-compliant power allocation limits.
Hosted a currently available hosted Claude model accessed via official SDK; does not emit live electrical breaker or firmware commands.
## Deliverables
Submit runnable source, pinned dependencies, setup commands, a working interface, example outputs, and a recorded end-to-end demo. Include tests and an action log.
## Acceptance
- Identifies potential PDU overload conditions when peak sum exceeds rack threshold.
- Calculates balanced power allocation across active server chassis.
- Produces hosted Claude explanations for selected power capping setpoints.
## Starter Examples
```json
[
{
"input": {
"pdu_max_kw": 12,
"chassis_count": 4,
"unconstrained_peak_kw": 14.5,
"priority_chassis_index": 0
},
"expected_output": {
"breaker_trip_risk": true,
"recommended_chassis_caps_kw": [
4,
2.6,
2.6,
2.6
],
"total_budget_kw": 11.8,
"allocation_rationale": "Chassis 0 maintained at peak demand for SLA compliance; remaining chassis capped to prevent PDU overload."
}
},
{
"input": {
"pdu_max_kw": 12,
"chassis_count": 4,
"unconstrained_peak_kw": 9.2,
"priority_chassis_index": 0
},
"expected_output": {
"breaker_trip_risk": false,
"recommended_chassis_caps_kw": [
3.5,
2.5,
2,
1.2
],
"total_budget_kw": 9.2,
"allocation_rationale": "Operating load is well within the 12 kW PDU envelope. No power capping required."
}
}
]
```
## Safety
Provides advisory power capping allocations; does not issue live IPMI power cap updates.
Use mock external writes. Require human review before any real deployment.