Sensor Calibration Assistant with Google ADK

Field technicians calibrating complex chemical sensors like Emerson's Rosemount 350A need step-by-step interactive verification tools. In this challenge, developers will use Google ADK to build a light, voice- or text-driven calibration assistant that guides operators through buffer immersion and zero-point offset steps.

EngineeringHosted by Vera
Challenge brief

What you are building

The core problem, expected build, and operating context for this challenge.

Construct a step-by-step sensor calibration guide using Google ADK to assist operators with Rosemount 350A pH sensors.

Delivery guide

How work is evaluated

Evaluation

Evaluates calculation of electrode slope percentage based on test mV inputs.

Datasets

Challenge datasets

Public datasets, plus the private datasets you have access to.

Evaluation rubric

How submissions are scored

These dimensions define what the evaluator checks and which criteria separate a passable run from a strong one.

Dimensions
2 scoring checks
Binary
2 pass or fail dimensions
Ordinal
0 scaled dimensions
Dimension 1

Slope Accuracy Test

Slope > 95% must return pass_status = True

Binary check

This dimension contributes its full weight only when the submission satisfies the requirement. Partial credit is not awarded.

Dimension 2

Math Accuracy Score

Precision of slope calculation against theoretical Nernst equation value • target: 1 • range: 0-1

Binary check

This dimension contributes its full weight only when the submission satisfies the requirement. Partial credit is not awarded.

Learning goals

What you should walk away with

  • Configure a Google ADK agent for step-by-step procedural workflows

  • Parse operator millivolt (mV) readings during pH 4, 7, and 10 buffer tests

  • Calculate sensor slope percentage and flag degraded glass electrodes

  • Output calibration certificate documentation

Resources and assets

Reference links and supporting material

Dataset notes

Synthetic pH sensor calibration test records and buffer voltage measurements.

Challenge setup

Evaluates calculation of electrode slope percentage based on test mV inputs.

Challenge input

JSON with mv_ph4, mv_ph7

Google ADK

Assigned framework

Evaluated output

JSON with calculated_slope_pct, pass_status (boolean)

Evaluation checks
  • Slope > 95% must return pass_status = True
  • Precision of slope calculation against theoretical Nernst equation value • target: 1 • range: 0-1
Configured evaluation evidence
  • Benchmark: Industrial Math & Calculation Benchmark
  • Math Accuracy Score target: 1
  • 1 public reference case
Configured runtime
  • Python execution harness
  • Python sandbox (unavailable on Versalist)

Summary shows the first task, up to three tools, and up to three evidence items. Open the technical recipe to view all configured items.

View technical recipe

Configured tools

Action Space
  • Google · Required
  • Google ADK · Optional
  • Google Jules · Optional
Orchestration
  • Google Jules · Optional

Evaluation contract

  • Slope Accuracy Test · Weight 1
  • Math Accuracy Score · Weight 1

Metrics

  • Math Accuracy Score · Target 1

Benchmarks

  • Industrial Math & Calculation Benchmark
  • general

Reference cases

  • 1 public reference case

Workflow tasks

  1. Task 1

    Input: JSON with mv_ph4, mv_ph7

    Output: JSON with calculated_slope_pct, pass_status (boolean)

    Execution harness: Python

Evaluation tools

  • Google ADK · Agent development kit

Recipe freeze marker

No recipe freeze time is recorded.

Frequently Asked Questions about Sensor Calibration Assistant with Google ADK