Build an Accelerator Interconnect Diagnosis and Packet Loss Reviewer
Analyze multi-GPU node interconnect counters and fabric error flags. Isolate degraded PCIe and NVLink links causing distributed all-reduce slowdowns and propose hardware repair actions.
What you are building
The core problem, expected build, and operating context for this challenge.
Analyze multi-GPU node interconnect counters and fabric error flags. Isolate degraded PCIe and NVLink links causing distributed all-reduce slowdowns and propose hardware repair actions.
Cluster Network Engineer
Ingest normalized interconnect counter logs, CRC error rates, and replay counts.
Correlate interconnect packet drops with collective all-reduce latency degradation.
Prompt hosted Claude to inspect fabric topology anomalies and pinpoint failing lanes.
Synthesize a hardware maintenance ticket with port isolation and replacement guidance.
Network topology graph visualizer highlighting degraded links with click-to-generate repair tickets.
Construct synthetic interconnect telemetry tables recording link CRC errors, replay events, and NVLink/PCIe port states across 8-GPU nodes. Starter examples below are synthetic. They are not downloaded records.
NVIDIA DCGM exporter Extracts DCGM NVLink error metrics, replay counters, and bandwidth saturation indicators from the DCGM exporter counters.
anthropic-claude, pydantic-ai. Interprets multi-hop interconnect error patterns and drafts clear, actionable physical maintenance steps. Hosted Claude API for topological reasoning and maintenance ticket drafting. No access to proprietary cloud network routing.
Submit runnable source, pinned dependencies, setup commands, a working interface, example outputs, and a recorded end-to-end demo. Include tests and an action log.
Identifies failing interconnect links based on replay threshold exceedance (>1000/hr).
Correlates link errors with distributed collective step latency degradation.
Outputs structured repair tickets specifying switch port, GPU index, and replacement part.
```json [ { "input": { "node_id": "hpc-gpu-node-12", "fabric_errors": [ { "gpu_src": 2, "gpu_dst": 3, "link_id": "nvlink-1", "crc_errors": 45120, "replay_count": 8900 }, { "gpu_src": 0, "gpu_dst": 1, "link_id": "nvlink-0", "crc_errors": 0, "replay_count": 0 } ], "step_time_ms": 340.5, "baseline_step_time_ms": 180 }, "expected_output": { "fault_detected": true, "isolated_component": "GPU 2 -> GPU 3 NVLink 1", "degradation_pct": 89.2, "repair_action": "Reseat high-speed mezzanine interconnect or replace interposer ribbon cable on slot 2-3", "ticket_priority": "urgent" } }, { "input": { "node_id": "hpc-gpu-node-03", "fabric_errors": [ { "gpu_src": 0, "gpu_dst": 1, "link_id": "nvlink-0", "crc_errors": 2, "replay_count": 1 } ], "step_time_ms": 181.2, "baseline_step_time_ms": 180 }, "expected_output": { "fault_detected": false, "isolated_component": "None", "degradation_pct": 0.6, "repair_action": "Maintain routine monitoring; error rate within allowable transient threshold", "ticket_priority": "low" } } ] ```
Diagnostic analysis only; does not reset physical PCIe registers or disable cluster switch fabrics. Use mock external writes. Require human review before any real deployment.
Participation guide
Diagnostic analysis only; does not reset physical PCIe registers or disable cluster switch fabrics. Use mock external writes and human review.
How work is evaluated
Identifies failing interconnect links based on replay threshold exceedance (>1000/hr). Correlates link errors with distributed collective step latency degradation. Outputs structured repair tickets specifying switch port, GPU index, and replacement part.
Runnable source, pinned dependencies, setup commands, working interface, example outputs, recorded demo, tests, and action logs.
Challenge datasets
Public datasets, plus the private datasets you have access to.
How submissions are scored
These dimensions define what the evaluator checks and which criteria separate a passable run from a strong one.
Complete workflow
Ingest normalized interconnect counter logs, CRC error rates, and replay counts. Correlate interconnect packet drops with collective all-reduce latency degradation. Prompt hosted Claude to inspect fabric topology anomalies and pinpoint failing lanes. Synthesize a hardware maintenance ticket with port isolation and replacement guidance.
Missing or incorrect.
Partly complete, with documented gaps.
Complete, with reproducible evidence.
Correctness and evidence
Identifies failing interconnect links based on replay threshold exceedance (>1000/hr). Correlates link errors with distributed collective step latency degradation. Outputs structured repair tickets specifying switch port, GPU index, and replacement part.
Missing or incorrect.
Partly complete, with documented gaps.
Complete, with reproducible evidence.
Review interface
Network topology graph visualizer highlighting degraded links with click-to-generate repair tickets.
Missing or incorrect.
Partly complete, with documented gaps.
Complete, with reproducible evidence.
Safe execution
Diagnostic analysis only; does not reset physical PCIe registers or disable cluster switch fabrics.
This dimension contributes its full weight only when the submission satisfies the requirement. Partial credit is not awarded.
What you should walk away with
Ingest normalized interconnect counter logs, CRC error rates, and replay counts.
Correlate interconnect packet drops with collective all-reduce latency degradation.
Prompt hosted Claude to inspect fabric topology anomalies and pinpoint failing lanes.
Synthesize a hardware maintenance ticket with port isolation and replacement guidance.
Reference links and supporting material
Construct synthetic interconnect telemetry tables recording link CRC errors, replay events, and NVLink/PCIe port states across 8-GPU nodes. Supplied starter examples are synthetic, not source extracts.
Challenge setup
Configuration summary for this challenge.
Challenge input
Input details are not configured.
Anthropic Claude
LLM for code generation & more
Evaluated output
No output checks are configured.
- Ingest normalized interconnect counter logs, CRC error rates, and replay counts. Correlate interconnect pac...
- Identifies failing interconnect links based on replay threshold exceedance (>1000/hr). Correlates link erro...
- Network topology graph visualizer highlighting degraded links with click-to-generate repair tickets.
- 2 public reference cases
- 1 configured tool
Summary shows the first task, up to three tools, and up to three evidence items. Open the technical recipe to view all configured items.
View technical recipe
Configured tools
- Anthropic Claude · Optional
Evaluation contract
- Complete workflow · Weight 40
- Correctness and evidence · Weight 30
- Review interface · Weight 20
- Safe execution · Weight 10
Reference cases
- 2 public reference cases
Workflow tasks
No workflow tasks are configured.
Recipe freeze marker