Build a District Water Pressure and Leak Outage Coordinator
Evaluate municipal water distribution pipe isolation schedules during planned repair outages using hydraulic simulation models. Pinpoint low-pressure customer nodes and formulate fire-flow preservation plans.
What you are building
The core problem, expected build, and operating context for this challenge.
Evaluate municipal water distribution pipe isolation schedules during planned repair outages using hydraulic simulation models. Pinpoint low-pressure customer nodes and formulate fire-flow preservation plans.
Water network utility planner
Ingest pipe break repair requests, valve isolation boundaries, and hydraulic node configurations.
Model network pressure fluctuations and fire hydrant delivery capabilities using WNTR simulation modules.
Identify critical demand nodes falling below minimum operational pressure during the planned shutdown window.
Generate a structured pipe outage playbook and tank water dispatch routing plan for district engineers.
Interactive network topology map showing isolated pipes, impacted pressure zones, and tank water delivery routes.
Use WNTR example network INP files with synthetic customer demand patterns and maintenance tickets. Starter examples below are synthetic. They are not downloaded records.
Water Network Tool for Resilience Leverages WNTR hydraulic resilience and pressure-dependent demand simulation features to isolate network pipes.
haystack, wntr, pydantic. Searches municipal utility operating manuals and valve operating standards to assemble repair guidance dossiers. Local or hosted LLM with standard Python runtime support for running hydraulic simulations.
Submit runnable source, pinned dependencies, setup commands, a working interface, example outputs, and a recorded end-to-end demo. Include tests and an action log.
Executes a simulated valve isolation in WNTR to compute customer node pressure drops.
Flags any junction node dropping below 20 psi during peak hourly demand intervals.
Produces an isolation ticket specifying sequence of valve closures and contingency water dispatch points.
```json [ { "input": { "work_order_id": "WO-PIPE-782", "pipe_to_isolate": "P-104", "scheduled_start": "2025-07-10T22:00:00Z", "duration_hours": 4, "affected_valves": [ "V-12", "V-15" ], "network_junction_pressures_psi": { "J-101": 42.5, "J-102": 38, "J-103": 24.1 } }, "expected_output": { "simulation_status": "FEASIBLE_WITH_CAUTION", "min_simulated_pressure_psi": 21.4, "critical_nodes": [ "J-103" ], "fire_flow_maintained": true, "tanker_dispatch_required": false, "approved_by_hydraulics_lead": false } }, { "input": { "work_order_id": "WO-PIPE-789", "pipe_to_isolate": "P-202", "scheduled_start": "2025-07-11T14:00:00Z", "duration_hours": 6, "affected_valves": [ "V-30", "V-34", "V-39" ], "network_junction_pressures_psi": { "J-205": 31, "J-208": 18.2, "J-210": 15.4 } }, "expected_output": { "simulation_status": "UNACCEPTABLE_PRESSURE_DROP", "min_simulated_pressure_psi": 12.1, "critical_nodes": [ "J-208", "J-210" ], "fire_flow_maintained": false, "tanker_dispatch_required": true, "approved_by_hydraulics_lead": false } } ] ```
Simulation does not actuate municipal telemetry or send commands to physical SCADA controllers. Use mock external writes. Require human review before any real deployment.
Participation guide
Simulation does not actuate municipal telemetry or send commands to physical SCADA controllers. Use mock external writes and human review.
How work is evaluated
Executes a simulated valve isolation in WNTR to compute customer node pressure drops. Flags any junction node dropping below 20 psi during peak hourly demand intervals. Produces an isolation ticket specifying sequence of valve closures and contingency water dispatch points.
Runnable source, pinned dependencies, setup commands, working interface, example outputs, recorded demo, tests, and action logs.
Challenge datasets
Public datasets, plus the private datasets you have access to.
How submissions are scored
These dimensions define what the evaluator checks and which criteria separate a passable run from a strong one.
Complete workflow
Ingest pipe break repair requests, valve isolation boundaries, and hydraulic node configurations. Model network pressure fluctuations and fire hydrant delivery capabilities using WNTR simulation modules. Identify critical demand nodes falling below minimum operational pressure during the planned shutdown window. Generate a structured pipe outage playbook and tank water dispatch routing plan for district engineers.
Missing or incorrect.
Partly complete, with documented gaps.
Complete, with reproducible evidence.
Correctness and evidence
Executes a simulated valve isolation in WNTR to compute customer node pressure drops. Flags any junction node dropping below 20 psi during peak hourly demand intervals. Produces an isolation ticket specifying sequence of valve closures and contingency water dispatch points.
Missing or incorrect.
Partly complete, with documented gaps.
Complete, with reproducible evidence.
Review interface
Interactive network topology map showing isolated pipes, impacted pressure zones, and tank water delivery routes.
Missing or incorrect.
Partly complete, with documented gaps.
Complete, with reproducible evidence.
Safe execution
Simulation does not actuate municipal telemetry or send commands to physical SCADA controllers.
This dimension contributes its full weight only when the submission satisfies the requirement. Partial credit is not awarded.
What you should walk away with
Ingest pipe break repair requests, valve isolation boundaries, and hydraulic node configurations.
Model network pressure fluctuations and fire hydrant delivery capabilities using WNTR simulation modules.
Identify critical demand nodes falling below minimum operational pressure during the planned shutdown window.
Generate a structured pipe outage playbook and tank water dispatch routing plan for district engineers.
Reference links and supporting material
Use WNTR example network INP files with synthetic customer demand patterns and maintenance tickets. Supplied starter examples are synthetic, not source extracts.
Challenge setup
Configuration summary for this challenge.
Challenge input
Input details are not configured.
Haystack
Framework
Evaluated output
No output checks are configured.
- Ingest pipe break repair requests, valve isolation boundaries, and hydraulic node configurations. Model net...
- Executes a simulated valve isolation in WNTR to compute customer node pressure drops. Flags any junction no...
- Interactive network topology map showing isolated pipes, impacted pressure zones, and tank water delivery r...
- 2 public reference cases
- 1 configured tool
Summary shows the first task, up to three tools, and up to three evidence items. Open the technical recipe to view all configured items.
View technical recipe
Configured tools
- Haystack · Optional
Evaluation contract
- Complete workflow · Weight 40
- Correctness and evidence · Weight 30
- Review interface · Weight 20
- Safe execution · Weight 10
Reference cases
- 2 public reference cases
Workflow tasks
No workflow tasks are configured.
Recipe freeze marker